Hydrolysis resistance test of poly(propylene carbonate) polyurethane elastomer
Category: Technical Information
Date: 2020-12-18
Click: 786
Author: admin

Prepare a batch of samples according to the aforementioned elastomer synthesis method, then shape them into a certain shape according to the national standard, put them in 70℃ water, hydrolyze them at constant temperature for 2-4 weeks, take them out, and dry them at 80℃ for 24 hours to test their performance.


Table Comparison of tensile strength retention rate of polypropylene carbonate type, polyether type and polyester polyurethane elastomer

Project

Week

Week

Week

Week

Polypropylene carbonate type

100

96.84

98.1

98.63

Polybutylene adipate

100

100.51

87.87

65.36

Polyether type

100

95.93

98.89

92.96

Table: Comparison of tear strength retention rate of polypropylene carbonate type, polyether type, and polyester polyurethane elastomer

Project

0 Week

Week

Week

Week

Polypropylene carbonate type

100

91.73

81.95

88.72

Polybutylene adipate

100

92.04

79.39

76.81

Polyether type

100

98.63

94.2

98.3


Note: Polyester is butylene adipate with a molecular weight of 3000, polyether is N220, and polypropylene carbonate is a product with a molecular weight of 3000.

The test results show that with the extension of the hydrolysis time, the polyimide carbonate and polyether polyurethane elastomer basically do not undergo hydrolysis, and the tensile strength and tear strength basically do not change after 2-4 weeks of hydrolysis. With the extension of the hydrolysis time, the tensile strength and tear strength of the polyester polyurethane elastomer gradually increase. After 4 weeks, the tensile strength is only about 65% of the initial, and severe hydrolysis occurs.

 